20 Spyder3 GigE Vision SG-14 Monochrome Cameras User’s Manual
03-032-20123-01 Teledyne DALSA
Step 2. Connect Power, Ethernet, and Trigger
Cables
WARNING! Grounding Instructions
Static electricity can damage electronic components. Please discharge any static electrical
charge by touching a grounded surface, such as the metal computer chassis, before performing
any hardware installation.
The use of cable types and lengths other than those specified may result in increased emission or
decreased immunity and performance of the camera.
Figure 11: Input and Output, trigger, and Power Connectors
Power Connector
WARNING: It is extremely important that you apply the appropriate voltages to your camera.
Incorrect voltages may damage the camera. Input voltage requirement: +12 V to +15 V DC.
The camera requires a single 6-pin Hirose connector with a single voltage input +12 VDC to +15 VDC for
power. The camera meets all performance specifications using stand ard sw itching power supplies,
although well-regulated linear supplies provide optimum performance.
Pin
Description
1, 2, 3
Supply voltageMin +12 VDC to Max +15 VDC
4, 5, 6
Ground
Table 6. Hirose 6-Pin Power Pinout
Hirose 6-pin Circular Male
5
4
6
2
3
1
Mating Part: HIROSE
HR10A-7P-6S
!
!